SMPP ESME trunk settings reference#

This reference describes the fields available when creating or editing an SMPP ESME trunk, and the connection details shown in the trunk’s credentials window. The settings are grouped by the sections of the trunk form in the DIDWW User Panel.

For configuration steps, see Create an SMPP ESME trunk or Manage SMPP ESME trunks. This page covers trunk settings only. For protocol details, see the SMPP specification.

General settings#

The General section identifies the trunk, sets its DIDWW SMPP server location, and restricts the IP addresses that can connect.

Field

Availability

Description

Friendly name

Required

Unique name used to identify the trunk. For example, My SMPP ESME SMS Trunk.

System type

Optional

Value that categorizes the type of ESME that binds to the DIDWW SMSC. For example, VMS (voice mail system) or OTA (over-the-air activation system). Your application sends this value as the system_type bind parameter.

Server location

Required

DIDWW SMPP server location of the trunk: US, NY or NL, AMS. The location determines the host that your application binds to. Your firewall must allow your application to open connections to the IP address of the location. See Server locations and IP addresses.

Allowed IP addresses

Optional

IP addresses from which connections are allowed, in the format (IPv4|IPv6)[/mask]. For example, 203.0.113.10/32. Entries in any other format are marked as invalid. If the field is empty, all IP addresses are allowed.

Source address settings#

The Source Address Settings section controls which DID numbers can be used as the sender ID for outbound SMS.

Field

Availability

Description

Allow any DID(s) for SMS OUT

Optional

Controls how sender IDs are assigned. When the toggle is on, all DIDs with Outbound P2P SMS enabled in your account can be used as the sender ID. When the toggle is off, only the numbers in Allowed source addresses can be used. Default: on.

Available source addresses

Optional

DIDs that you can add to Allowed source addresses when Allow any DID(s) for SMS OUT is off. The list shows only DIDs that support outbound P2P SMS, with their Country, Number, and Description. Filters: Source address, Description, Country, and Region.

Allowed source addresses

Optional

DIDs that can be used as the sender ID when Allow any DID(s) for SMS OUT is off. Only the numbers in this list are available as sender IDs.

Trunk group settings#

The optional Trunk Group Configuration section assigns the trunk to an existing SMS trunk group.

Field

Availability

Description

Assign to trunk group

Optional

Existing SMS trunk group to which the trunk is assigned.

Priority

Optional

Priority of the trunk within the selected trunk group. It determines the order in which trunks are used. The system attempts to contact the target SMS trunk with the highest-numbered priority first. Trunks with the same priority are tried in a random order. Range: 0 to 32767. Default: 1.

Credentials and connection information#

DIDWW generates the trunk credentials when the trunk is created. The credentials window shows them together with the connection details and a summary of the trunk’s access settings. To open it, see View SMPP ESME trunk credentials.

Field

Description

Host

Host that your application binds to. It matches the trunk’s Server location: us.sms-out.didww.com for US, NY or eu.sms-out.didww.com for NL, AMS.

Port

Port for SMPP over plain TCP: 2775. For SMPP over TLS, use port 2776 with the same credentials, and set the TLS server name (SNI) and hostname verification to sms-out.didww.com. See SMPP over TLS.

System ID

Identifies your ESME in the bind request. Used as the system_id bind parameter.

Password

Used with the System ID for authentication. Used as the password bind parameter. The password is hidden until you click the eye icon. To replace the credentials, see Regenerate SMPP ESME trunk credentials.

System Type

Value of the trunk’s System type field. Used as the system_type bind parameter.

Allowed IPs

IP addresses configured in Allowed IP addresses. Empty when all IP addresses are allowed.

Allowed Source Addresses

Source addresses that the trunk allows, as configured in Source Address Settings. Shows Any when Allow any DID(s) for SMS OUT is on.